MWM TCG 2020 Gas Engine

For Highly Economical Plant Operation

MWM TCG 2020 Gas Engine

The economical MWM TCG 2020 gas engine is deployed around the globe for power generation in CHP plants. The series features an electrical output range from 1,000 to 1,560 kW and supports operation with all types of gas, including natural gas, biogas, landfill gas, sewage gas, mine gas, and other gases.

Low Operating and Maintenance Costs

The TCG 2020 V12 variant in the RW (natural gas) and XW (biogas) configurations is optimized for the electrical output band of 1 MW, with even lower operating and maintenance costs. The MWM TCG 2020 K gas engine was especially adapted to non-ISO conditions such as high altitudes or high intake air temperatures in the field of natural gas.

More than 2,000 Installed MWM Generator Sets Worldwide

Owing to the broad application spectrum, the series is deployed for energy generation in various industries, such as recycling plants, district heating supply, healthcare, greenhouses, industrial companies, and IPP projects. More than 2,000 MWM TCG 2020 generator sets with an electrical output of approximately 2,800,000 kW are installed worldwide.

Benefits at a Glance

High Energy Efficiency

Wide Range of Applications

  • The MWM TCG 2020 is ideal for energy generation in recycling plants, district heating supply, healthcare, greenhouses, industrial companies, and IPP projects
  • Adaptable to the requirements of a wide range of industries
  • Efficient solution for modern energy systems
Reduced Operating Costs

High Reliability

  • Few interruptions due to long maintenance intervals
  • Ideal for continuous operation in demanding environments
  • Long useful life and high reliability enable uninterrupted operation
Flexibility in Operation

Lower Operating Costs

  • Up to 50 percent less lubricating oil consumption
  • Longer maintenance intervals for all natural gas applications, for an up to two years longer useful life of the engine
  • Optimized electrical efficiency of 43 percent (under ISO conditions) for natural gas applications

FAQ: MWM TCG 2020 Gas Engine

Why is the MWM TCG 2020 an Ideal Choice for Plant Operators?

With its high efficiency, low operating costs, flexibility in the choice of fuel, and compact design, the MWM TCG 2020 is ideal for numerous industrial applications.

For which Applications is the MWM TCG 2020 Especially Suitable?

The MWM TCG 2020 gas engine can be deployed for energy generation in various segments, such as recycling plants, district heating supply, healthcare, greenhouses, industrial companies, and IPP projects.

What are the Benefits the MWM TCG 2020 Series in Terms of Operating Costs?

The low lubricating oil consumption and long maintenance intervals have a positive effect on operating costs.

What are the Benefits of Using the MWM TCG 2020 in CHP Plants?

The TCG 2020 series increases energy efficiency, reduces operating costs, and cuts pollutant emissions.

What is the Output of the MWM TCG 2020 Gas Engines?

The TCG 2020 generator sets generate energy in an electrical output range from 1,000 to 1,560 kW.

The MWM TCG 2020 Series in Action

Combined Heat and Power (CHP)

Combined Heat and Power (CHP)

In CHP plants, MWM TCG 2020 gas engines generate heat and power for the energy supply.

Energy Transition

Energy Transition

The MWM TCG 2032 gas engine series can be operated with natural gas with a hydrogen admixture of up to 25 vol%.

Waste to Energy

Waste-to-Energy (WtE)

Through the efficient use of biogas, landfill gas, and sewage gas, MWM TCG 2020 generator sets convert waste into usable energy.

Utility & Independent Power Producers (IPP)

Utilities & Independent Power Producers (IPP)

The engines of the MWM TCG 2020 series are suitable for independent power producers, as it enables efficient distributed energy generation for IPP projects.

Distributed Power Generation

Distributed Power Generation

The MWM TCG 2020 series has a wide range of applications and is used for distributed energy generation in numerous industries.

Industry

Industry

MWM TCG 2020 engines generate heat, power, and waste heat for industrial processes, continuously supplying the company with energy.

Your Sales and Service Request

Technical Innovations for the Energy Supply of Tomorrow

Contact the MWM Sales Team now

The MWM Sales team is eager to answer any questions you may have about MWM gas engines, cogeneration power plants, service, and spare parts.

Contact MWM Service now

Our competent MWM Service team will help you with your service requests.

We are Ready for Your Future Projects

Download Product Brochures

TCG 2020 Procuct Brochure

The MWM TCG 2020 Gas Engine Series at Glance

Eight pages of information about the gas engine with the highest ratings in ecology and economy. These high-performance power generators offer high efficiency with low maintenance costs.

NOTICE: Click this brochure to access the digital publishing platform issuu.com. This website is governed by the issuu Privacy Policy.

All languages on issuu:

EN | ESDEFR | NL | CN

Download PDF:

EN | ESDEFR | NL | CN

Performance Data – MWM TCG 2020 Gas Engine

Natural Gas Applications, NOx ≤ 500 mg/Nm3 *

TCG 2020 V12
RW = Optimized for high total efficiency at requested power
Engine type 50 Hz
Electrical output kW 1000
Thermal output ± 8% kW 1056
Electrical efficiency % 43.0
Thermal efficiency % 45.4
Total efficiency % 88.4
Power to heat ratio ** 0.95
TCG 2020 V12 K
K = Optimized for robustness and low CAPEX
Engine type 50 Hz 60 Hz
Electrical output kW 1125 1125
Thermal output ± 8% kW 1251 1262
Electrical efficiency % 41.0 40.7
Thermal efficiency % 45.6 45.6
Total efficiency % 86.6 86.3
Power to heat ratio ** 0.90 0.89
TCG 2020 V12
R = Optimized for high total efficiency
Engine type 50 Hz 60 Hz
Electrical output kW 1200 1200
Thermal output ± 8% kW 1189 1196
Electrical efficiency % 43.7 43.4
Thermal efficiency % 43.3 43.2
Total efficiency % 87.0 86.6
Power to heat ratio ** 1.00 1.00

 

TCG 2020 V16 K
K = Optimized for robustness and low CAPEX
Engine type 50 Hz 60 Hz
Electrical output kW 1500 1500
Thermal output ± 8% kW 1675 1686
Electrical efficiency % 40.9 40.6
Thermal efficiency % 45.7 45.7
Total efficiency % 86.6 86.3
Power to heat ratio ** 0.89 0.89
TCG 2020 V16
R = Optimized for high total efficiency
Engine type 50 Hz 60 Hz
Electrical output kW 1560 1560
Thermal output ± 8% kW 1576 1589
Electrical efficiency % 43.3 43.0
Thermal efficiency % 43.8 43.8
Total efficiency % 87.1 86.8
Power to heat ratio ** 0.99 0.98

* “after commissioning (E10)”

The values given in this table are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.

Biogas, Landfill Gas, and Sewage Gas Applications, NOx ≤ 500 mg/Nm3 *

TCG 2020 V12
XW = Optimized for operation with biogases at requested power
Engine type 50 Hz
Electrical output kW 1000
Thermal output ± 8% kW 1035
Electrical efficiency % 42.6
Thermal efficiency % 44.1
Total efficiency % 86.7
Power to heat ratio ** 0.97
TCG 2020 V12
X = Optimized for operation with biogases
Engine type 50 Hz 60 Hz
Electrical output kW 1200 1200
Thermal output ± 8% kW 1192 1201
Electrical efficiency % 43.0 42.7
Thermal efficiency % 42.7 42.7
Total efficiency % 85.7 85.4
Power to heat ratio ** 1.00 1.00

 

TCG 2020 V16
X = Optimized for operation with biogases
Engine type 50 Hz 60 Hz
Electrical output kW 1560 1560
Thermal output ± 8% kW 1566 1580
Electrical efficiency % 42.7 42.3
Thermal efficiency % 42.9 42.8
Total efficiency % 85.6 85.1
Power to heat ratio ** 1.00 0.99

* 5% O2 and dry exhaust gases
** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.

The values given in this table are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.

Specifications and Service Intervals of the MWM TCG 2020 Gas Engine

Dimensions and Weights

TCG 2020 V12
RW = Optimized for high total efficiency at requested power
XW = Optimized for operation with biogases at requested power
Engine type 50 Hz
Length mm 4660
Width mm 1810
Height mm 2210
Dry weight genset kg 11200
Bore / stroke mm 170/195
Displacement dm3 53.1
Speed min-1 1500
Mean piston speed m/s 9.8
TCG 2020 V12 K
K = Optimized for robustness and low CAPEX
Engine type 50 Hz 60 Hz
Length mm 4790 5970
Width mm 1810 1790
Height mm 2210 2210
Dry weight genset kg 11700 13000
Bore / stroke mm 170/195 170/195
Displacement dm3 53.1 53.1
Speed min-1 1500 1500
Mean piston speed m/s 9.8 9.8
TCG 2020 V12
R = Optimized for high total efficiency
X = Optimized for operation with biogases
Engine type 50 Hz 60 Hz
Length mm 4790 5970
Width mm 1810 1790
Height mm 2210 2210
Dry weight genset kg 11700 13000
Bore / stroke mm 170/195 170/195
Displacement dm3 53.1 53.1
Speed min-1 1500 1500
Mean piston speed m/s 9.8 9.8

 

TCG 2020 V16 K
K = Optimized for robustness and low CAPEX
Engine type 50 Hz 60 Hz
Length mm 5430 6640
Width mm 1810 1790
Height mm 2210 2210
Dry weight genset kg 13300 14900
Bore / stroke mm 170/195 170/195
Displacement dm3 70.8 70.8
Speed min-1 1500 1500
Mean piston speed m/s 9.8 9.8
TCG 2020 V16
R = Optimized for high total efficiency
X = Optimized for operation with biogases
Engine type 50 Hz 60 Hz
Length mm 5430 6640
Width mm 1810 1790
Height mm 2210 2210
Dry weight genset kg 13300 14900
Bore / stroke mm 170/195 170/195
Displacement dm3 70.8 70.8
Speed min-1 1500 1500
Mean piston speed m/s 9.8 9.8

* On request

The values given in this table are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.

Service Intervals

TCG 2020 V12, V16, V12 K, V16 First service (check valve clearance) Cylinder head inspection Major overhaul
Natural gas, purified biogas, sewage gas, and landfill gas 4000 oh 32000 oh* 64000 oh
Unpurified biogas, sewage gas, and landfill gas 2000 oh 16000 oh* 64000 oh
TCG 2020 V12
RW = Optimized for high total efficiency at requested power
XW = Optimized for operation with biogases at requested power
First service (check valve clearance) Cylinder head inspection Major overhaul
Natural gas 4000 oh 40000 oh* 80000 oh
Purified biogas, sewage gas, and landfill gas 4000 oh 32000 oh* 64000 oh
Unpurified biogas, sewage gas, and landfill gas 2000 oh 16000 oh* 64000 oh

* “after commissioning (E10)”

The values given in this table are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.