MWM TCG 2032 / 2032B Gas Engine
Your Engine for Independent Power Producer (IPP) Projects
The MWM TCG 2032 and TCG 2032B gas engines can be used in numerous areas of application for power generation. Due to their high flexibility and reliability, the gensets are ideally suited for municipal utilities, industrial plants, recycling plants, and greenhouses. The TCG 2032 gas engines features an electrical output range of 3,000 kW to 4,500 kW and supports all types of gas, including natural gas, landfill gas, sewage gas, mine gas, coking gas, biogas, and hydrogen admixtures of up to 25 vol%.
Reliable Power and Heat Generation
The engines of the TCG 2032 series are used in particular in the IPP sector with an electrical output of 100 MW and more, as continuous and reliable power and generation is essential in the industry. The TCG 2032 gensets in the electrical output range of 3,000 kW to 4,500 kW can be used flexibly for all types of gas, including natural gas, landfill gas, sewage gas, mine gas, coking gas, biogas, and hydrogen admixtures of up to 25 vol% with natural gas.
Fast-Ramp-Up Option for an Even Faster Start-Up
The TCG 2032B V16 gas engine with fast-ramp-up option offers plant operators an even higher output and improved operational reliability and is ideally suited for demanding applications in the refinery and petrochemical industry. The MWM TCG 2032 and TCG 2032B V16 gensets offer plant operators not only low operating costs and extended maintenance intervals, but also high reliability. Their compact design facilitates transportation and enables smooth installation, making the engines ideal for projects with a demanding power supply.
Benefits at a Glance
Flexible Deployment Options
- Ideal for demanding energy generation using combined heat and power generation
- Suitable for various industries and applications, e.g. utilities and independent power producers, industrial companies, and recycling facilities
- Output ranges from 3,000 kW to 4,500 kW
Operational Versatility
- High flexibility regarding energy generation requirements changes in various industries
- MWM TCG 2032B V16 also available with fast ramp-up
- Suitable for all types of gas, including natural gas, landfill gas, sewage gas, mine gas, coking gas, biogas, and hydrogen admixtures of up to 25 vol% with natural gas
High Availability and Reliability
- The TCG 2032 series boasts outstanding reliability and low maintenance costs
- Longer maintenance intervals reduce operating costs
- Turbocharger technology increases gas engine availability
FAQ: MWM TCG 2032 / 2032B Gas Engine
What are the Benefits of the TCG 2032 Series for Industrial Applications?
The sturdiness, compact engine design, and high performance make the gas engines ideal for continuous use in the industry and for IPP projects, where reliability and efficiency are crucial.
What are the Maintenance Benefits of the MWM TCG 2032 and TCG 2032B Gas Engines?
Thanks to the longer maintenance intervals and integrated lubricating oil systems, the time spent on maintenance and maintenance costs are reduced, resulting in higher operating efficiency.
Why do the MWM TCG 2032 and TCG 2032B Generator Sets Occupy So Little Space?
The compact design of the TCG 2032 series enables a high power density in a small area, which is particularly beneficial for facilities where space is limited.
What are the Cost Benefits of MWM TCG 2032 and TCG 2032B Engines for Plant Operators?
Due to their low lubricating oil consumption, long maintenance intervals, and high efficiency, the engines stand out with low operating costs and enable quick amortization of the investment costs.
What Types of Gas Can the MWM TCG 2032 and 2032B Be Operated With?
The gensets are suitable for all types of gas, including natural gas, landfill gas, sewage gas, mine gas, coking gas, biogas, and natural gas with a hydrogen admixture of up to 25 vol%.
The MWM TCG 2032 Series in Action
Applications with the MWM TCG 2032 Gas Engine
Learn More About Reference Cases on the International MWM Website:
Your Sales and Service Request
Technical Innovations for the Energy Supply of Tomorrow
Download Product Brochures
The MWM TCG 2032 Gas Engine Series at Glance
Here you will find complete information about gas engines in the TCG 2032 series. Like all MWM power generators, these gas engines run on various types of fuels and are capable of effectively utilizing exhaust heat through cogeneration.
NOTICE: Click this brochure to access the digital publishing platform issuu.com. This website is governed by the issuu Privacy Policy.
All languages on issuu:
Download PDF:
MWM 25H2-Kit for TCG 2032 and TCG 2032B Gas Engines
The brochure for MWM TCG 2032 gas engines shows the parts and components included in the retrofit 25H2-Kit for a hydrogen admixture of up to 25 vol%.
NOTICE: Click this brochure to access the digital publishing platform issuu.com. This website is governed by the issuu Privacy Policy.
All languages on issuu:
Download PDF:
Performance Data – MWM TCG 2032 Gas Engine
Natural Gas Applications, NOx ≤ 500 mg/Nm3 *
TCG 2032 V12 R = Optimized for high total efficiency |
|||
---|---|---|---|
Engine type | 50 Hz | 60 Hz** | |
Electrical output | kW | 3333 | 3000 |
Mean effective pressure | bar | 20.0 | 20.1 |
Thermal output ± 8% | kW | 3238 | 2877 |
Electrical efficiency | % | 43.9 | 43.9 |
Thermal efficiency | % | 42.6 | 42.1 |
Total efficiency | % | 86.5 | 85.9 |
Power to heat ratio*** | 1.03 | 1.04 |
TCG 2032 V16 R = Optimized for high total efficiency |
|||
---|---|---|---|
Engine type | 50 Hz | 60 Hz** | |
Electrical output | kW | 4300 | 4000 |
Mean effective pressure | bar | 19.4 | 20.2 |
Thermal output ± 8% | kW | 4164 | 3866 |
Electrical efficiency | % | 44.1 | 43.8 |
Thermal efficiency | % | 42.7 | 42.4 |
Total efficiency | % | 86.8 | 86.2 |
Power to heat ratio*** | 1.03 | 1.03 |
TCG 2032B V16 R = Optimized for high total efficiency |
|||
---|---|---|---|
Engine type | 50 Hz | 60 Hz** | |
Electrical output | kW | 4500 | 4050 |
Mean effective pressure | bar | 20.3 | 20.4 |
Thermal output ± 8% | kW | 4361 | 3891 |
Electrical efficiency | % | 44.6 | 44.3 |
Thermal efficiency | % | 43.2 | 42.6 |
Total efficiency | % | 87.8 | 86.9 |
Power to heat ratio*** | 1.03 | 1.04 |
* 5% O2 and dry exhaust gases
** On request
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
Natural Gas Applications with 25 vol% Hydrogen (NOx ≤ 500 mg/Nm3* / 1.0 g/bhph*)
TCG 2032 V12 R+ High Response plus 25H2-Kit = Optimized for high total efficiency with 25 vol.% hydrogen kit |
|||
---|---|---|---|
Engine type | 50 Hz | 60 Hz | |
Electrical output*** | kW | 3,333 | 3,000 |
Electrical efficiency | % | 43.7 | 43.7 |
Thermal efficiency** (±8 %) | % | 42.7 | 42.1 |
Total efficiency | % | 86.4 | 85.8 |
Power to heat ratio**** | 1.02 | 1.03 |
TCG 2032 V16 R+ High Response plus 25H2-Kit = Optimized for high total efficiency with 25 vol.% hydrogen kit |
|||
---|---|---|---|
Engine type | 50 Hz | 60 Hz | |
Electrical output*** | kW | 4,300 | 4,000 |
Electrical efficiency | % | 44.0 | 43.8 |
Thermal efficiency** (±8 %) | % | 42.8 | 42.5 |
Total efficiency | % | 86.8 | 86.3 |
Power to heat ratio**** | 1.03 | 1.03 |
TCG 2032B V16 R+ High Response plus 25H2-Kit = Optimized for high total efficiency with 25 vol.% hydrogen kit |
|||
---|---|---|---|
Engine type | 50 Hz | 60 Hz | |
Electrical output*** | kW | 4,500 | 4,050 |
Electrical efficiency | % | 44.5 | 44.3 |
Thermal efficiency** (±8 %) | % | 43.3 | 42.7 |
Total efficiency | % | 87.8 | 87.0 |
Power to heat ratio**** | 1.03 | 1.04 |
* 5% O2 and dry exhaust gases
** Exhaust gas cooled to 120 °C for natural gas
*** According to ISO 3046-1
**** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
Biogas, Landfill Gas, and Sewage Gas Applications, NOx ≤ 500 mg/Nm3 *
TCG 2032 V16 X = Optimized for operation with biogases |
|||
---|---|---|---|
Engine type | 50 Hz | 60 Hz** | |
Electrical output | kW | 3770 | 3510 |
Mean effective pressure | bar | 17.0 | 17.0 |
Thermal output ± 8% | kW | 3487 | 3117 |
Electrical efficiency | % | 42.9 | 43.3 |
Thermal efficiency | % | 39.7 | 38.5 |
Total efficiency | % | 82.7 | 81.8 |
Power to heat ratio*** | 1.08 | 1.12 |
* 5% O2 and dry exhaust gases
** On request
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The values given in this table are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
Specifications and Service Intervals of the MWM TCG 2032 Gas Engine
Dimensions and Weights
TCG 2032 V12 | |||
---|---|---|---|
Engine type | 50 Hz | 60 Hz* | |
Length | mm | 7860 | 8000 |
Width | mm | 2660 | 2790 |
Height | mm | 3390 | 3390 |
Dry weight genset | kg | 43100 | 49780 |
Bore / stroke | mm | 260/320 | 260/320 |
TCG 2032 V16 | |||
---|---|---|---|
Engine type | 50 Hz | 60 Hz* | |
Length | mm | 9271 | 9420 |
Width | mm | 2790 | 2790 |
Height | mm | 3390 | 3390 |
Dry weight genset | kg | 51200 | 52400 |
Bore / stroke | mm | 260/320 | 260/320 |
* On request
The values given in this table are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
Service Intervals
First service (check valve clearance)* | Mixture cooler cleaning | |
---|---|---|
Natural gas | 4,000 oh | 20,000 oh |
Cylinder head inspection | Major overhaul | |
---|---|---|
Natural gas | 40,000 oh | 80,000 oh |
* “after commissioning (E10)”
The values given in this table are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.