The MWM TCG 3016 V16 S gas engine is specially designed for natural gas applications. The genset combines best-in-class power density with low plant investment costs. Thanks to an electrical output of 1 MW and a thermal output of 1.1 MW, the engine is optimized for a high load and availability.

Improved Lubrication Oil Management

Thanks to the larger integrated lubricating oil volume, plant operators benefit from significantly longer oil change intervals and simplified oil management with the MWM TCG 3016 V16 S.

Outstanding Price-Performance Ratio

The high power density and small footprint enables plant operators to generate maximum energy in a limited space, making the TCG 3016 V16 S gas engine particularly attractive for industrial applications. Other benefits of the engine include rapid amortization of the plant and low lubricating oil consumption.

Benefits at a Glance

High Energy Efficiency

Maximum Power Density and Energy Generation

  • Output range from 1,000 kW (electrical) and 1,100 kW (thermal)
  • Ideal for all natural gas applications in 50 Hz grids
  • High electrical efficiencies of up to 41.5 percent
Reduced Operating Costs

High Economic Efficiency

  • Low plant investment costs
  • Maximum efficiency, small installation area
  • Low investment and service costs
Flexibility in Operation

Maintenance-Friendly Design

  • Lowest-in-class lube oil consumption
  • Integrated oil and refill tanks
  • Longer oil change intervals

FAQ: MWM TCG 3016 V16 S Gas Engine

How Efficient Is the MWM TCG 3016 V16 S Gas Engine?

The engine achieves an electrical efficiency of up to 41.5 percent, which makes it particularly energy-efficient and economical for plant operators.

What Is the Output of the MWM TCG 3016 V16 S Genset?

The MWM TCG 3016 V16 S delivers an electrical output of 1,000 kW and a thermal output of 1,100 kW. This combination makes it ideal for use in CHP plants.

What Are the Benefits of the MWM TCG 3016 V16 S for Plant Operators in Terms of Investment Costs?

Thanks to its compact design and small setup area, the TCG 3016 V16 S stands out with low plant investment costs, resulting in rapid plant amortization.

What Are the Benefits of the MWM TCG 3016 V16 S in Terms of Operating Costs?

The TCG 3016 V16 S boasts the lowest lubricating oil consumption in its class as well as longer oil change intervals and integrated oil management, resulting in significantly reduced operating costs for plant operators.

Why Is the MWM TCG 3016 V16 S Particularly Easy to Maintain?

The gas engine features longer oil change intervals and integrated oil and refill tanks, which minimize the maintenance overhead and maximize system availability.

The MWM TCG 3016 V16 S in Action

Combined Heat and Power (CHP)

Combined Heat and Power (CHP)

In CHP plants, MWM TCG 3016 V16 S gas engines generate heat and power for the energy supply.

Utility & Independent Power Producers (IPP)

Utilities & Independent Power Producers (IPP)

The MWM TCG 3016 V16 S generator sets are suitable for independent power producers, as they enable efficient and distributed power generation for IPP projects.

Distributed Power Generation

Distributed Power Generation

The MWM TCG 3016 series is used for heat and power supply in distributed energy generation applications.

Industry

Industry

The MWM TCG 3016 V16 S engines generate heat, power, and waste heat for industrial processes, continuously supplying the company with energy.

Product Video for the MWM TCG 3016 Gas Engine

Download Product Brochures

Product Brochure TCG 3016 V16 S

MWM TCG 3016 V16 S Gas Engine – One Megawatt.

Further information on the TCG 3016 V16 S gas engines (S = high power density) is available here.

NOTICE: Click this brochure to access the digital publishing platform issuu.com. This website is governed by the issuu Privacy Policy.

All languages on issuu:

EN | ESDEFR | TR | CN

Download PDF:

EN | ESDEFR | TR | CN

Your Sales and Service Request

Technical Innovations for the Energy Supply of Tomorrow

Contact the MWM Sales Team now

The MWM Sales team is eager to answer any questions you may have about MWM gas engines, cogeneration power plants, service, and spare parts.

Contact MWM Service now

Our competent MWM Service team will help you with your service requests.

We are Ready for Your Future Projects

Performance Data – MWM TCG 3016 V16 S Gas Engine

Natural Gas Applications, NOx ≤ 500 mg/Nm3 *

TCG 3016 V16
S = High density
Engine type 50 Hz
Electrical output kW 1,000
Medium effective pressure bar 23.5
Thermal output ± 8% kW 1,123
Electrical efficiency % 41.5
Thermal efficiency % 46.6
Overall efficiency % 88.1
Power to heat ratio ** 0.89

* 5% O2 and dry exhaust gases
** On request
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.

The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.

Specifications and Service Intervals of the MWM TCG 3016 V16 S Gas Engine

Dimensions and Weights

TCG 3016 V16
S = High density
Engine type 50 Hz
Bore / Stroke mm 132/160
Displacement dm3 35.0
Speed min-1 1,500
Mean piston speed m/s 8.0
Length mm 4,200
Width mm 1,780
Height mm 2,150
Dry weight genset kg 8,560

* On request

The values given in this table are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.

Service Intervals

  First
Service *
Spark plug
change
Natural gas 2,000 Oh *** 4,000 Oh
  Cylinder head
inspection
General
overhaul
Natural gas 32,000 Oh ** 64,000 Oh

* “after commissioning (E10)”

The values given in this table are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.